Specifications
| S.NO | PARAMETERS |
REQIREMENTS |
|
|
|
General Requirements |
||
|
1. |
Charger Capacity |
60 – 480 KW |
|
|
2. |
Model No. |
ENC-DCL060B |
|
|
|
Input Requirements |
||
|
3. |
AC Supply System |
Three-Phase, 5 Wire AC system (ENC) |
|
|
4. |
Nominal Input Voltage |
AC380V ±15% (ENC) |
|
|
5. |
Input Frequency |
50/60Hz |
|
|
Environmental Requirements |
|||
|
6. |
Ambient Temperature Range |
-25 to 55°C |
|
|
7. |
Ambient Humidity |
5 to 95% |
|
| 8. | Storage Temperature |
-40 to 70°C |
|
|
|
Mechanical Requirements |
||
|
9. |
IP Ratings |
IP 54 |
|
|
10. |
Cooling |
Air-cooled |
|
|
|
Output Requirements |
||
|
11. |
Number of Outputs |
2 •one gun charged,60kw max output •two guns charged, 30kw max each output |
|
|
12. |
Output Voltage |
DC 150-1000V |
|
|
13. |
Output Connector Compatibility |
IEC 62196 2017, IEC 61851 2017, SAE J1772, etc. |
|
|
14. |
Power Factor |
≥0.99 (50% load above) |
|
|
|
Communication Requirements |
||
|
15. |
Emergency Stop Switch |
Support |
|
|
16. |
Display |
21 INches Adv Screen & 21.1 inches touch screen with shell |
|
|
17. |
User Authentication |
Mobile Application or User Interface / QR Code / RFID Card / Password (Optional) |
|
|
18. |
Metering Information |
Consumption Units |
|
|
User Interface & Display Requirements |
|||
|
19. |
Communication between EVSE and Central Server |
OCPP 1.6J Protocol (Optional) |
|
|
20. |
Metering |
Grid Responsive Metering as Per Units’ Consumption of Each Vehicle |
|
|
21. |
Interface between charger and CMS |
Ethernet / 3G / 4G / WIFI (Optional) |
|
|
22. |
Safety Parameters |